Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
JAMA Health Forum ; 4(2): e225610, 2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36826829

RESUMO

This cross-sectional study examines the characteristics of prior authorization policies for new drugs in Medicare Part D to understand whether they are consistent with US Food and Drug Administration indications.


Assuntos
Medicare Part D , Estados Unidos , Autorização Prévia , Cobertura do Seguro , Políticas
4.
Gynecol Oncol ; 125(1): 65-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22155417

RESUMO

OBJECTIVE: Evaluate and compare the effectiveness of CA125, HE4, Mesothelin and MMP7 marker levels to monitor ovarian cancer patients after surgery and chemotherapy. Evaluate the lead time of a rise of marker levels before recurrence. METHODS: The study consists of 23 patients with advanced stage ovarian/fallopian tube cancer. Blood was drawn after front line surgery and chemotherapy treatment and at 3 month intervals thereafter. One patient had chemoresistant disease, two patients remained in remission and 20 patients had recurring disease and were used for marker evaluation. RESULTS: In five patients HE4 was the only marker to elevate before recurrence with a lead time of up to 4½ months including one patient who did not have a CA125 response at all. In a further two patients, HE4 increased before CA125 did. In four of these seven patients, HE4 levels were consistently at or above threshold during remission when both CA125 and imaging results were negative. MMP7 elevated before recurrence in one patient who was negative for the other markers. Mesothelin elevated in two patients who were also positive for CA125 and HE4. CONCLUSIONS: HE4 can predict ovarian cancer recurrence earlier than CA125 and it can be elevated in patients that do not express CA125 at sufficient levels to make a clinical decision. MMP7 and Mesothelin have lower potential as markers for ovarian cancer recurrence to complement CA125. A failure of HE4 levels to normalize at completion of standard therapy may indicate a poor prognosis.


Assuntos
Biomarcadores Tumorais/sangue , Antígeno Ca-125/sangue , Proteínas Ligadas por GPI/sangue , Metaloproteinase 7 da Matriz/sangue , Proteínas de Membrana/sangue , Neoplasias Ovarianas/diagnóstico , Proteínas/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Seguimentos , Humanos , Mesotelina , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/terapia , Recidiva , Proteína 2 do Domínio Central WAP de Quatro Dissulfetos
5.
J Natl Cancer Inst ; 103(21): 1630-4, 2011 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-21917606

RESUMO

In screening for epithelial ovarian cancer, unnecessary surgery can be reduced by limiting use of transvaginal ultrasound (TVU) to women with increasing CA125 serum levels. Replacing or augmenting TVU with measurement of a serum marker specific for malignancy might further improve screening performance. Serum samples from 112 invasive ovarian cancer patients and 706 matched control subjects from the Prostate, Lung, Colorectal, and Ovarian trial were used to evaluate human epididymis protein 4 (HE4), mesothelin, matrix metalloproteinase 7 (MMP7), SLPI, Spondin2, and insulin-like growth factor binding protein 2 (IGFBP2) for their potential use in screening. TVU results were available for a subset of 84 patients and 516 control subjects used to compare the best marker with TVU. HE4 was found to perform better than TVU as a second-line screen, confirming 27 of 39 cancers with increasing CA125 serum levels compared with 17 cancers confirmed by TVU (P = .03). Serum HE4 levels were found to increase with age and smoking status, suggesting that a longitudinal algorithm might improve its performance.


Assuntos
Biomarcadores Tumorais/sangue , Carcinoma/diagnóstico , Proteínas Secretadas pelo Epidídimo/metabolismo , Programas de Rastreamento/métodos , Neoplasias Ovarianas/diagnóstico , Adulto , Idoso , Envelhecimento/sangue , Antígeno Ca-125/sangue , Carcinoma/sangue , Carcinoma/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fumar/sangue , Ultrassonografia/métodos , Vagina , beta-Defensinas
6.
Langmuir ; 25(23): 13510-5, 2009 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19928944

RESUMO

A 10-fold improvement in the signal-to-noise (S/N) ratio of an optically encoded silica particle-based immunoassay was achieved through incorporating a protein resistant poly(ethylene glycol) (PEG) surface layer and optimizing antibody immobilization conditions. PEG was activated using 2,2,2-trifluoroethanesulfonyl chloride (tresyl) and required a minimum reaction time of 1.5 h. The activated PEG had a reactive half-life of approximately 5 h when stored in acidified dimethyl sulfoxide (DMSO). By increasing the protein incubation time and concentration, a maximum antibody loading on the particle surface of 1.6 x 10(-2) molecules per nm(2) was achieved. The assay S/N ratio was assessed using a multiplexed multicomponent optically encoded species-specific immunoassay. Encoded particles were covalently grafted or nonspecifically coated with either bovine or mouse IgG for the simultaneous detection of complementary anti-IgG "target" or uncomplementary anti-IgG "noise". The versatility and potential as a serum-based assay platform was demonstrated by immobilizing either a polyclonal antibody or an engineered single-chain variable fragment (scFv) capture probe on particles for the detection of the ovarian cancer biomarker, mesothelin (MSLN). The MLSN antigen was spiked into PBS buffer or 50% human serum. Both capture probe orientations, and media conditions showed similar low level detection limits of 5 ng/mL; however, a 40% decrease in maximum signal intensity was observed for assays run in 50% serum.


Assuntos
Imunoensaio/métodos , Animais , Bovinos , Proteínas Ligadas por GPI , Humanos , Glicoproteínas de Membrana/análise , Mesotelina , Camundongos , Nanopartículas/química , Polietilenoglicóis/química , Sulfonas/química
7.
Clin Cancer Res ; 14(9): 2647-55, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18451228

RESUMO

PURPOSE: To measure circulating antigens, sandwich ELISA assays require two complementary affinity reagents. Mouse monoclonal antibodies (mAb) and polyclonal antibodies (pAb) are commonly used, but because their production is lengthy and costly, recombinant antibodies are emerging as an attractive alternative. EXPERIMENTAL DESIGN: We developed a new class of recombinant antibodies called biobodies (Bb) and compared them to mAb for use in serodiagnosis. Bbs were secreted biotinylated in vivo by diploid yeast and used as affinity reagents after Ni purification. Bead-based assays for HE4 and mesothelin were developed using Bbs in combination with pAbs (Bb/pAb assays). To assess precision, reproducibility studies were done using four runs of 16 replicates at six analyte levels for each marker. Pearson correlations and receiver-operator characteristic analyses were done in 214 patient serum samples to directly compare the Bb/pAb assays to mAb assays. Diagnostic performance of the Bb/pAb assay was further assessed in an expanded set of 336 ovarian cancer cases and controls. RESULTS: On average across analyte levels, Bb/pAb assays yielded within-run and between-run coefficients of variations of 11.7 and 23.8, respectively, for HE4 and 14.0 and 14.5, respectively, for mesothelin. In the subset (n = 214), Pearson correlations of 0.95 for HE4 and 0.92 for mesothelin were observed between mAb and Bb/pAb assays. The area under the curves for the mAb and Bb/pAb assays were not significantly different for HE4 (0.88 and 0.84, respectively; P = 0.20) or mesothelin (0.74 and 0.72, respectively; P = 0.38). CONCLUSION: Yeast-secreted Bbs can be used reliably in cost-effective yet highly sensitive bead-based assays for use in large validation studies.


Assuntos
Anticorpos/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Proteínas Secretadas pelo Epidídimo/metabolismo , Glicoproteínas de Membrana/sangue , Neoplasias Ovarianas/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/imunologia , Biotinilação , Proteínas Secretadas pelo Epidídimo/imunologia , Feminino , Proteínas Ligadas por GPI , Humanos , Glicoproteínas de Membrana/imunologia , Mesotelina , Pessoa de Meia-Idade , Neoplasias Ovarianas/imunologia , Neoplasias Ovarianas/metabolismo , Engenharia de Proteínas , Proteínas Recombinantes de Fusão/imunologia , Proteínas Recombinantes de Fusão/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Leveduras/genética , beta-Defensinas
8.
PLoS One ; 2(12): e1281, 2007 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-18060075

RESUMO

BACKGROUND: Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies. METHODOLOGY AND PRINCIPLE FINDINGS: We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer. CONCLUSIONS: Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias Ovarianas/sangue , Manejo de Espécimes , Antígeno Ca-125/sangue , Estudos de Casos e Controles , Feminino , Humanos , Oxirredutases Intramoleculares/sangue , Fatores Inibidores da Migração de Macrófagos/sangue , Prolactina/sangue , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA